RACK
80 series
UV-C disinfection system |
||
![]() |
|||||||||
| RACK 80 series |
80/4
|
80/5
|
80/6
|
80/8
|
80/10
|
80/12
|
80/15
|
80/18
|
|
| Max. flow rate (m³/h) |
30
|
40
|
65
|
80
|
135
|
000
|
250
|
345
|
|
| N° of lamps |
4
|
5
|
6
|
8
|
10
|
12
|
15
|
18
|
|
| Plumbing connections (PN10) |
DN
80
|
DN
80
|
DN
100
|
DN
100
|
DN
150
|
DN
150
|
DN
200
|
DN
200
|
|
| Upper side openable |
no
|
no
|
yes
|
yes
|
yes
|
yes
|
yes
|
yes
|
|
| Power absorption (W±2%) |
320
|
400
|
480
|
640
|
800
|
90
|
1200
|
1440
|
|
| Electrical panel dimensions (mm) |
500x400x250
|
500x400x250
|
500x400x250
|
700x400x250
|
700x400x250
|
700x400x250
|
700x400x250
|
1000x400x250
|
|
| RACK ELECTRICAL PANEL | |
| Control of the general working by programmable micro-processor |
![]() |
| Plant working hour-meter | |
| Resettable lamp working hour-meter | |
| Check that lamps are working properly | |
| Monitoring the temperature inside the electrical panel | |
| Programmable multi-function display | |
| Memory blocking of identity number of any faulty lamp | |
| NA/NC free contact - 220 V NA/NC outlet - 5A max | |
| RS port for pC connection | |
| General trip switch | |
| Electrical supply 230-240V, 50-60 Hz | |
| Visual alarm for faults | |
| Monitoring of temperature and irradation, with pre-set alarm tresholds | |
|
Automatic switching off of the system for high temperature of the panel / UV chamber |
|
| ON REQUEST : | |
| 4-20 mA outlet | |
| Telecontrol system with telephonic controller | |
| Remote shutdown system (24V) | |
| Ö-Norm / DVGW approved sensor | |
| Dimensional sketches |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Filtermat
filters your reliable partner
|
|||
| Filtermat filters |
|
||
| Telephone | +32-3-711.03.57 or +32-3-710.65.50 | ||
| Fax | +32-3-711.03.58 or +32-3-710.65.58 | ||
| Address | Winninglaan 17, B-9140 Temse (Belgium) | ||
| info@filtermat.be | |||
| Website | www.filtermat.be | ||